24 Core Single Mode Fiber Optic Cable Price
Release time: 2023-10-12

Fibre Optic Multicore Cable 24 Core Tight Buffered Singlemode 9/125 OS2

Single Mode Fiber Optic Cable Details

Traditionally used in riser and vertical installations predominantly for internal applications where the inner fibres are protected by a 900µm coating layered with aramid yarn and covered with an outer fire resistant jacket. Nowadays, the cable jackets also contain water resistance and UV stabilised properties meaning they can also be used outside of the building as well.
Available in fibre counts from 2-24 core, tight buffered cables are extremely easy to prepare for termination or fusion splicing.
Further protection to the cables can be applied by way of additional jackets, steel braid or armouring.

9/50 125 Fiber Optic Cable Application and Installation

  1. 1.This distribution or mini-break-out cable can be used for many indoor applications and outdoor applications
  2. 2.OFC 4/24 core cable features our new and improved ES9 tight buffer.
  3. 3.Typical cable applications include: LAN and WAN backbones, central office interconnections, backbones in data centres, and many other.
  4. 4.Fiber Optic Cable Single Mode Price is suited for installation in ducts and on trays.
  5. 5.Single mode fiber and multimode fiber optic cables feature an UV stabilised, water and moisture resistant sheathing, the cable is thus well suited for outdoor runs; but is not longitudinal water blocked.

24 Core Single Mode Fiber Optic Cable Physical properties

Physical properties   IEC 60794-1-2
Attribute Method Limits
Fibre count   2 4 6 8 12 16 24
Nominal diameter  [mm]   6 6.5 6.5 7.0 7.5 8.0 8.5
Nominal weight [kg/km]   32 34 36 39 43 52 63
Maximum installation load (a few hours)[N]   1500 2100 2400
Short term tensile strength(some days)[N] E1 1000 1400 1600
Permanent tensile strength [N] E1 500 1000 1500
Impact  [J] E4 20]
Crush(compressive strength) E3 3000 N/ 100 mm
Torsion E7 5 cycles±1 turn
Minimum bending radius E11 50 75 115
Minimum bending radius under tension E18A 100 130 230
Temperature range F1 Operation and Installation
Storage
-20 C to 70℃
-40  ℃  to70C
Minimum bending radius of the ES9 tightly
buffered fibres
G01 With standard fibres
With MaxCap-BB-OMx fibres
With BendBright-XS fibers:
20
7.5
7.5
mm
mm
mm
Heat  of  combustion  [MJ/km]- [kW/m]   660
0.18
760
0.21
845
0.23
970
0.29
1180
0.33
1400
0.39
1700
0.47
Related products
SIP-3 SIPn-3 AAsXS AAsXSn Wires for Overhead Power Lines
SIP-3 SIPn-3 AAsXS AAsXSn Wires for Overhead Power Lines
Covered Protected Aluminum Cable (ABNT NBR 11873)
Covered Protected Aluminum Cable (ABNT NBR 11873)
Amka Cable Low Voltage Twsit Overhead Cable
Amka Cable Low Voltage Twsit Overhead Cable Amka
15kV 25kV 35kV Medium Voltage Semi-insulated Cable(CFE EO000-29 )
15kV 25kV 35kV Medium Voltage Semi-insulated Cable(CFE EO000-29 )