Stranded Bare Copper Conductors Description
Bare copper cable offers a low impedance and is the essential component of a grounding system. Its applications are wide, it is often used in excavations as an earth electrode, or buried in concrete foundation in civil engineering.Uni Industry Group Co., Ltd. offers a range of bare copper cables (annealed or not) with cross sections starting from 6 to 300mm². Other sections are also available on request. The composition of the cable strands varies from 7 to 37 strands. The manufacturing process meets the requirements of the IEC EN 60228: class 2 bare copper conductors for grounding installations.
Find out more about the characteristics of the electrod, lightning protection conductors as per IEC EN 62561-2 standard : Lightning Protection System Components - Part 2: Requirements for Conductors and Earth Electrodes
Dimensions and composition of bare copper cables
Characteristics of bare copper cables | ||||||||
Nominal cross-section (mm²) | Number and wire dia. (mm) | Outer dia. (mm) | Number and wire dia. (mm)mm) | Outer dia. (mm)font> | Number and wire dia. (mm) | Outer dia. (mm) | Number and wire dia. (mm) | Outer dia. (mm) |
10 | 7 X 1.43 | 4.1 | 19 X 0.80 | 4.2 | 37 X 0.60 | 4.2 | – | – |
16 | 7 X 1.71 | 5.1 | 19 X 1.03 | 5.2 | 37 X 0.75 | 5.2 | – | – |
25 | 7 X 2.13 | 6.4 | 19 X 1.30 | 6.5 | 37 X 0.90 | 6.4 | – | – |
29 | – | – | 19 X 1.40 | 7.0 | – | – | – | – |
35 | 7 X 2.53 | 7.6 | 19 X 1.53 | 7.7 | 37 X 1.10 | 7.7 | – | – |
50 | 7 X 3 | 9 | 19 X 1.77 | 9.2 | 37 X 1.31 | 9.2 | – | – |
70 | 7 X 3.56 | 10.7 | 19 X 2.14 | 10.9 | 37 X 1.55 | 10.9 | – | – |
95 | – | – | 19 X 2.52 | 12.5 | 37 X 1.81 | 12.7 | 61 X 1.40 | 12.6 |
120 | – | – | 19 X 2.84 | 14.2 | 37 X 2.05 | 14.2 | 61 X 1.60 | 14.4 |
150 | – | – | 19 X 3.18 | 15.9 | 37 X 2.21 | 16 | 61 X 1.77 | 15.9 |
185 | – | – | – | – | 37 X 2.50 | 17.7 | – | – |
240 | – | – | – | – | 37 X 2.83 | 19.8 | – | – |
300 | – | – | – | – | 37 X 3.21 | 22.5 | – | – |
400 | – | – | – | – | – | – | 61 X 2.89 | 26 |
500 | – | – | – | – | – | – | 91 X 2.65 | 29.1 |
CUR CÂBLE NU CÂBLE DE MISE À LA TERRE
Code Imacab | Section (mm²) | Diamètre extérieur nominal (mm) | Masse approx +/-1% (Kg/Km) | Résistance électrique max à 20°C (Ω/Km) | Conditionnement standard T : Touret (m) |
CUR6 | 6 | 2.87 | 52 | 3.08 | C 100/50m / T 10000 |
CUR10 | 10 | 3.70 | 85 | 1.83 | T 5000 |
CUR16 | 16 | 4.65 | 137 | 1.15 | T 3500 |
CUR25 | 25 | 5.98 | 217 | 0.727 | T 2000 |
CUR35 | 35 | 6.84 | 300 | 0.524 | T 1500 |
CUR50 | 50 | 8.06 | 403 | 0.387 | T 1200 |
CUR70 | 70 | 9.70 | 594 | 0.268 | T 800 |
CUR95 | 95 | 11.35 | 820 | 0.193 | T 600 |
CUR120 | 120 | 12.75 | 1032 | 0.153 | T 1000 |
CUR146 | 146 | 14.10 | 1316 | 0.128 | T 1000 |
CUR150 | 150 | 14.20 | 1260 | 0.124 | T 1000 |
CUR185 | 185 | 15.95 | 1585 | 0.0991 | T 600 |
CUR240 | 240 | 18.50 | 2100 | 0.0754 | T 500 |