YOUR CURRENT POSITION: Home > Product > Bare Conductor
TACSR, TACSR/AW Thermal Resistant Aluminum Alloy Conductors, Steel (Or Aluminum-Clad Steel) Reinforced

TACSR, TACSR/AW Thermal Resistant Aluminum Alloy Conductors, Steel (Or Aluminum-Clad Steel) Reinforc

Thermal resistant aluminium alloy conductor, steel reinforced; TACSR & TACSR-G

TACSR, TACSR/AW Application
TACSR- Thermal Resistant Aluminum Alloy Conductors, Steel (Or Aluminum-Clad Steel) Reinforced used for overhead power transmission lines.
TACSR, TACSR/AW Construction
Reinforced Core (ST, AW) : Zinc-coated steel Wire or Aluminum-clad steel Wire(AW): 14% ~ 40% IACS conductivity
Conductor : Thermal Resistant Aluminum Alloy Wire used for continuously allowable temperature up to 150°C
TACSR, TACSR/AW Characteristics
Aluminum-Clad steel wire (AW) Type has excellent rustless characteristics.
TACSR, TACSR/AW Standard
JEC 3406
Data Sheet

LS Cable & System Standard – 60% IACS Conductivity TAL

Conductor size

Cross-Section Area

Conductor Construction

Approx. Overall diameter

Approx. Overall weight

Maximum DC resistance at 20oC

Minimum breaking load

Modulus of Elasticity

Coefficient of Linear Expansion

Current Carrying Capacity

 

Thermal Aluminum TAL

Galvanized Steel ST

Thermal Aluminum TAL

Galvanized Steel ST

             

mm2

mm2

mm2

No.xmm

No.xmm

mm

kg/km

Ω/km

Kgf

Kgf/ mm2

x10-6/oC

A

58

57.73

9.621

6 x 3.5

1 x 3.5

10.5

233.1

0.505

1,980

8,400

18.9

343

80

83.10

13.85

6 x 4.2

1 x 4.2

12.6

335.5

0.350

2,770

8,400

18.9

430

95

95.40

15.90

6 x 4.5

1 x 4.5

13.5

385.2

0.306

3,810

8,400

18.9

478

80

79.64

21.24

15 x 2.6

4 x 2.6

13.0

385.7

0.368

4,720

9,390

17.6

448

100

99.08

26.42

15 x 2.9

4 x 2.9

14.5

479.9

0.296

5,580

9,390

17.6

517

120

120.6

32.17

15 x 3.2

4 x 3.2

16.0

584.4

0.243

5,550

9,390

17.6

590

120

124.7

29.09

30 x 2.3

7 x 2.3

16.1

573.7

0.237

5,540

9,080

18.0

598

160

159.3

37.16

30 x 2.6

7 x 2.6

18.2

732.8

0.185

6,980

9,080

18.0

706

200

198.2

46.24

30 x 2.9

7 x 2.9

20.3

911.7

0.149

8,640

9,080

18.0

816

240

241.3

56.29

30 x 3.2

7 x 3.2

22.4

1,110

0.122

10,210

9,080

18.0

932

330

326.8

52.84

26 x 4.0

7 x 3.1

25.3

1,320

0.0904

10,950

8,360

19.0

1,128

410

413.4

67.35

26 x 4.5

7 x 3.5

28.5

1,673

0.0714

13,910

8,360

19.0

1,322

480

483.8

33.54

45 x 3.7

7 x 2.47

29.6

1,599

0.0610

11,260

7,250

20.8

1,425

520

519.5

67.35

54 x 3.5

7 x 3.5

31.5

1,969

0.0569

15,600

7,990

19.5

1,504

610

612.4

79.38

54 x 3.8

7 x 3.8

34.2

2,320

0.0481

18,350

7,990

19.5

1,682

680

678.8

87.99

54 x 4.0

7 x 4.0

36.0

2,572

0.0436

19,810

7,990

19.5

1,797

680

684.5

46.24

45 x 4.4

7 x 2.9

35.1

2,260

0.0431

15,580

7,250

20.8

1,787

810

814.5

56.29

45 x 4.8

7 x 3.2

38.4

2,700

0.0363

18,480

7,250

20.8

2,004

1,160

1,163

96.95

84 x 4.2

7 x 4.2

46.2

3,996

0.0254

27,830

7,430

20.5

2,573

1,520

1,520

126.7

84 x 4.8

7 x 4.8

52.8

5,222

0.0195

36,390

7,430

20.5

3,035

LS Cable & System Standard – 20.3% IACS Conductivity AW

Conductor size

Cross-Section Area

Conductor Construction

Approx. Overall diameter

Approx. Overall weight

Maximum DC resistance at 20oC

Minimum breaking load

Modulus of Elasticity

Coefficient of Linear Expansion

Current Carrying Capacity

 

Thermal Aluminum TAL

Galvanized Steel ST

Thermal Aluminum TAL

Galvanized Steel ST

             

mm2

mm2

mm2

No.xmm

No.xmm

mm

kg/km

Ω/km

Kgf

Kgf/ mm2

x10-6/oC

A

120

124.7

29.08

30 x 2.3

7 x 2.3

16.1

536.5

0.219

5,540

8,100

19.2

622

160

159.3

37.16

30 x 2.6

7 x 2.6

18.2

685.4

0.171

6,980

8,100

19.2

734

200

198.2

46.24

30 x 2.9

7 x 2.9

20.3

852.8

0.138

8,640

8,100

19.2

847

210

241.3

56.29

30 x 3.2

7 x 3.2

22.4

1,038

0.113

10,160

8,100

19.2

968

330

326.8

52.84

26 x 4.0

7 x 3.1

25.3

1,252

0.0856

11,200

7,620

20.0

1,159

410

413.4

67.35

26 x 4.5

7 x 3.5

28.5

1,587

0.0676

14,230

7,630

20.0

1,358

480

483.84

33.54

45 x 3.7

7 x 2.47

29.6

1,561

0.0595

11,260

6,910

21.5

1,437

520

519.5

67.35

54 x 3.5

7 x 3.5

31.5

1,883

0.0544

15,920

7,390

20.4

1,537

610

612.4

79.38

54 x 3.8

7 x 3.8

34.2

2,219

0.0461

18,730

7,330

20.4

1,717

680

684.5

46.24

45 x 4.4

7 x 2.9

35.1

2,201

0.0422

15,580

6,900

21.5

1,805

810

814.5

56.29

45 x 4.8

7 x 3.2

38.4

2,628

0.0354

18,730

6,910

21.5

2,028

950

952.6

79.38

84 x 3.8

7 x 3.8

41.8

3,170

0.0302

23,780

7,030

21.2

2,292

1,160

1,163

96.95

84 x 4.2

7 x 4.2

46.2

3,872

0.0247

28,720

7,030

21.2

2,606

1,520

1,520

126.7

84 x 4.8

7 x 4.8

52.8

5,060

0.0189

37,520

7,030

21.2

3,075

LS Cable & System Standard – 20.3% IACS Conductivity AW

Conductor size

Cross-Section Area

Conductor Construction

Approx. Overall diameter

Approx. Overall weight

Maximum DC resistance at 20oC

Minimum breaking load

Modulus of Elasticity

Coefficient of Linear Expansion

Current Carrying Capacity

 

Thermal Aluminum TAL

Galvanized Steel ST

Thermal Aluminum TAL

Galvanized Steel ST

             

mm2

mm2

mm2

No.xmm

No.xmm

mm

kg/km

Ω/km

Kgf

Kgf/ mm2

x10-6/oC

A

120

124.7

29.08

30 x 2.3

7 x 2.3

16.1

528.9

0.217

5,410

7,980

19.4

625

160

159.3

37.16

30 x 2.6

7 x 2.6

18.2

675.7

0.170

6,810

7,980

19.4

736

200

198.2

46.24

30 x 2.9

7 x 2.9

20.3

840.7

0.136

8,440

7,980

19.4

854

210

241.3

56.29

30 x 3.2

7 x 3.2

22.4

1,024

0.112

10,210

7,980

19.4

973

330

326.8

52.84

26 x 4.0

7 x 3.1

25.3

1,238

0.085

10,950

7,540

20.2

1,163

410

413.4

67.35

26 x 4.5

7 x 3.5

28.5

1,570

0.0671

13,910

7,550

20.2

1,363

480

483.84

33.54

45 x 3.7

7 x 2.47

29.6

1,550

0.0592

11,110

6,880

20.6

1,441

520

519.5

67.35

54 x 3.5

7 x 3.5

31.5

1,865

0.0541

15,600

7,330

20.6

1,541

610

612.4

79.38

54 x 3.8

7 x 3.8

34.2

2,198

0.0458

18,350

7,320

20.6

1,722

680

684.5

46.24

45 x 4.4

7 x 2.9

35.1

2,189

0.0420

15,600

6,860

21.6

1,809

810

814.5

56.29

45 x 4.8

7 x 3.2

38.4

2,613

0.0353

18,480

6,880

21.6

2,031

950

952.6

79.38

84 x 3.8

7 x 3.8

41.8

3,149

0.0300

23,100

6,980

21.3

2,299

1,160

1,163

96.95

84 x 4.2

7 x 4.2

46.2

3,847

0.0246

28,270

6,980

21.3

2,611

1,520

1,520

126.7

84 x 4.8

7 x 4.8

52.8

5,027

0.0189

36,960

6,980

21.3

3,075


Contact Us, Now.
24-hour service hotline
Contact online customer service
Add: Technology Building, Tongbai Road, Zhongyuan District, Zhengzhou, Henan, China.
Related products
ACSS Aluminum Conductor Steel-supported Core
ACSS Aluminum Conductor Steel-supported Core
 Stacir /Aw & Hi-Stacir/AwSuper-Thermal Resistant Aluminum-Alloy Conductor, (High Tensile Strength) Aluminum-Clad Invar Reinforced
Stacir /Aw & Hi-Stacir/AwSuper-Thermal Resistant Aluminum-Alloy Conductor, (High Tensile Strength)
TAAAC TAL Thermal Resistant Aluminum Alloy Conductors
TAAAC TAL Thermal Resistant Aluminum Alloy Conductors
TACSR, TACSR/AW Thermal Resistant Aluminum Alloy Conductors, Steel (Or Aluminum-Clad Steel) Reinforced
TACSR, TACSR/AW Thermal Resistant Aluminum Alloy Conductors, Steel (Or Aluminum-Clad Steel) Reinforc
Related cases
Portuguese XHIV and LXHIV MV Cables
Portuguese XHIV and LXHIV MV Cables
XHIV and LXHIV Cable SpecificationBoth the LXHIV and XHIV are XLPE insulated and sheathed with PVC (Polyvinyl Chloride). It provides a +90oC operating temperatu
GYFTY53 Single-Armored Double-Jacket Direct Buried Cables
China GYFTY53 Single-Armored Double-Jacket Direct Buried Cables Manufacturer
China GYFTY53 Single-Armored Double-Jacket Direct Buried Cables ManufacturerOutside/Outdoor Fiber Optic CableSingle-Armored Double-Jacket Direct Buried Cables G
Lesotho OPGW-24B1-127 Optical Ground Wire Price
Lesotho OPGW-24B1-127 Optical Ground Wire Price from Manufacturer in China
Lesotho OPGW-24B1-127 Optical Ground Wire Price from Manufacturer in ChinaOPGW Cable Features 1.Preferred option for easy handling and splicing 2.Thick-walled a