YOUR CURRENT POSITION: Home > Product > Low Voltage Industrial Cables
LV Cable Voltage Level Up to 1.8/3kV

LV Cable Voltage Level Up to 1.8/3kV

PVC Insulated Power Cable 0.6/1KV; XLPE insulated power cable for 1.8/3KV and below PVC insulated cables with rated voltage of 450/750V and below; PVC insulated control cable;XLPE Insulated Control Cable;

PVC Insulated Power Cable

This product is used for power transmission and distribution lines with AC rated voltage of 1.8/3V and below.
Its mechanical and physical properties and electrical performance meet the requirements of national standard GB/T12706- 2008 and international standard IEC60502-2004 “Extruded Insulated Power Cable with Rate Voltage of 1-30KV and Accessories”. 

PVC Insulated Power Cable Operating characteristics and electrical performance

1. Cable laying temperature: ≥0°C
2. Long-term allowable operating temperature of cable conductor: ≤70°C
3. Higest working temperature of cable in case of short circuit (the longest lasting time is not over 5s): 160°C
4. Minimum permissible bending radius: Single core cable: 20D; multi-core cable: 15D (Note: D is actual outer diameter of cable).
5. AC withstand voltage test of finished cable product.
Rated voltage (KV) 0.6/1 1.8/3
Rated voltage (KV) 3.5 6.5
Duration (min) 5 5
6. Conductor DC resistance meets the requirements of national standard GB/T3956-2008 “Cable Conductor” and international standard IEC60228.Models, Names and Laying

Occasions of PVC Insulated Power Cable 

Model  
Name
 
Laying Occasion
Copper core Aluminum core
VV VLV PVC insulated and sheathed power cable Laid indoors, and in tunnels, pipelines, cable trenches, and flammable and severe corrosion places, and can not bear external mechanical forces.
VY VLY PVC insulated PE sheathed power cable Laid indoors, and in pipelines, cable trenches and severe corrosion places, and cannot bear external mechanical forces
VV22 VLV22 PVC insulated steel tape armored PVC sheathed power cable Laid indoors, and in cable trenches, underground severe corrosion places, and cannot bear tension.
VV23 VLV23 PVC insulated steel tape armored PE Laid indoors, and in cable trenches and underground severe corrosion place, and cannot bear tension.
VV32 VLV32 PVC insulated thin steel wire armored PVC sheathed power cable Laid under ground and in shafts, water and severe corrosion places, and cannot bear high tension.
VV33 VLV33 PVC insulated thin steel wire armored PVC sheathed power cable Laid under ground and in shafts, water and severe corrosion places, and can bear high tension.
VV42 VLV42 PVC insulated thick steel wire armored PVC sheathed power cable Laid under ground and in shafts and severe corrosion places, and can bear high tension.
VV43 VLV43 PVC insulated thick steel wire armored PE sheathed power cable Laid under ground and in shafts and severe corrosion places, and can bear high tension.

PVC Insulated Power Cable Range of production

Number of cores
Cross sectional Voltage level area (mm2) 
 
0.6/1
 
1.8/3
Single core 1 1.5-100 10-1000
Twin  core 2 1.5-240 10-240
Triple core 3 1.5-300 10-300
Three big cores and one small core 3+1 2.5-300 10-300
Fourth core 4 2.5-300 10-300
Fifth core 5 2.5-300 10-300
Three big cores and two small cores 3+2 2.5-300 10-300
Four big cores and one small core 4+1 2.5-300 10-300

XLPE insulated power cable for 1.8/3KV and below

 The product is applicable for AC 50Hz transmission and distribution lines with rated voltage of 1.8/3KV or below.
The mechanical properties and electrical performance of cables meet the requirements of national standard GB/T12706- 2008 and international standards IEC60502-2005.

XLPE insulated power cable Operating characteristics

1. Cable laying temperature: ≥0°C
2. Cable conductor long-term allowable working temperature:≤90°C
3. Higest working temperature of cable in case of short circuit (the longest lasting time is not over 5s): 250°C
4. Minimum allowable bending radius: Single core cable: 20D mm; multi-core cable: 15D mm Note: D is actual outer diameter of the cable

XLPE insulated power Cable models, names, and laying occasions

Model  
Name
 
Laying Occasion
Copper core Aluminum core
YJV YJLV XLPE insulated PVC sheathed power cable  
Laid indoors, and in tunnels and pipelines
YJY YJLY XLPE insulated PE sheathed power cable
YJV22 YJLV22 XLPE insulated steel tape armored PVC sheathed power cable Adapt for buried laying, not suitable for in-pipe laying
YJV23 YJLV23 XLPE insulated steel tape armored PE sheathed power cable
YJV32 YJLV32 XLPE insulated thin steel wire armored PVC sheathed power cable  
Laid on riverbeds of rivers or shallow water as connecting  lines  across  rivers  or  petroleum/natural gas platforms, also used in land high drop areas.
YJV33 YJLV33 XLPE insulated thin steel wire armored PVC sheathed power cable
YJV42 YJLV42 XLPE insulated thick steel wire armored PVC sheathed power cable
YJV43 YJLV43 XLPE insulated thick steel wire armored PE sheathed power cable

XLPE insulated power cable Range of production

Number of cores
Cross
 sectional area (mm2) 
 
0.6/1
 
1.8/3
Single core 1 1.5-1000 10-1000
Twin  core 2 1.5-240 10-240
Triple core 3 1.5-300 10-300
Three big cores and two small cores 3+2 2.5-300 10-300

PVC insulated cables with rated voltage of 450/750V and below

 This product is suitable for power, household appliances, instruments, small power tools, dynamic lighting and other applications with AC rated voltage (Uo/U) of 450/750V and below. 

PVC insulated cables with rated voltage of 450/750V and below Operating characteristics

1. Laying temperature: ≥0°C
2. Cable operating temperature: except 60227IEC07 (BV-90) and 60227IEC08 (RV-90), the maximum operating temperature is 90°C [the rest are 70°C].
3. Allowable bending radius: for cables with outer diameter (D) less than 25mm, should be not less than 4D; for cables with outer diameter (D) 25mm and above, should not be less than 6D.
 

Table of models, names and specifications of PVC insulated cables with rated voltage of 450/750V and below.

Model Original mode Product name Specificaiton (mm2)
60227IEC01 BV Single core hard conductor non-sheathed cable for general pupose 1 core 1.5-400
60227IEC02 RV Single core soft conductor non-sheathed cable for general pupose 1 core 1.5-240
 
60227IEC05
 
BV
Single core solid conductor non-sheathed cable (conductor temperature of 70°C) for internal wiring  
1 core 0.5-1.0
 
60227IEC06
 
RV
Single core solid conductor non-sheathed cable (conductor temperature of 70°C) for internal wiring  
1 core 0.5-1.0
 
60227IEC07
 
BV-90
Single core solid conductor non-sheathed cable (conductor temperature of 90°C) for internal wiring  
1 core 0.5-2.5
 
60227IEC08
 
RV-90
Single core solid conductor non-sheathed cable (conductor temperature of 90°C) for internal wiring  
1 core 0.5-2.5
60227IEC10 BVV Light PVC sheathed cable 2-5 cores 1.5-35
60227IEC43 SVR Fleixible wire for indoor decorative lighting circuit 1 core 0.5-0.75
60227IEC52 RVV Light PVC sheathed cable 2-3 cores 0.5-0.75
60227IEC53 RVV Ordinary PVC sheathed flexible wire 2-5 cores 0.75-2.5
60227IEC74 RVVYP Oil resistant PVC sheathed screened flexible cable 2-60 cores 0.5-2.5
60227IEC75 RVVY Oil resistant PVC sheathed screened flexible cable 2-60 cores 0.5-2.5
BLV   Aluminum core PVC insulated cable 1 core 2.5-400
BVV   Aluminum core PVC insulated PVC sheathed round cable 1 core 0.75-10
BLVV   Aluminum core PVC insulated PVC sheathed round cable 1 core 2.5-10
BLVVB   Aluminum core PVC insulated and sheathed parallel cable 2-3 cores 2.5-10
BVVB   Steel core PVC insulated and sheathed round cable 2-3 cores 0.75-10
BVR   Copper core PVC insulated flexible cable 1 core 2.5-10
BVVR   Copper core PVC shielded PVC sheathed flexible cable 1-3c ores 0.5-2.5

PVC insulated control cable

This product is used for electrical appliance and instrument connecting cables in power distribution equipment with AC rated voltage of 450/750V and below.
Its mechanical and physical properties and electrical performance meet the requirements of GB/T9330-2008 "Plastic Insulated Control Cable.
 

PVC Insulated Control Cable Operating characteristics

1. Cable laying temperature: ≥0°C
2. Long-term allowable operating temperature of cable conductor: 70°C
3. Minimum permissible bending radius:
a. For unarmored cables, should be no less than six times of cable outer diameter;
b. For armored or copper belt shield structure cables, should be not less than 12 times of cable outer diameter;
c. For flexible cable with shield structure, shoud be less than six times of cable outer diameter.
4. Finished cable can bear AC 5HZ, 3KV, 5min withstand test without breakdown.
5. Conductor DC resistance meets the requirements of national standard GB/T3956-2008 “Cable Conductor” and international standard IEC60228.
 

PVC Insulated Control Cable Models, Names and Laying Occasions

Model Name Laying Occasion
KVV Copper core PVC insulated PVC sheathed control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions.
KVVP Copper core PVC insulated PVC sheathed braid shield control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding.
KVVP2 Copper core PVC insulated PVC sheathed braid shield control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding.
KVV22 Copper core PVC insulated PVC sheathed copper belt shield control cable Laid indoors, and in cable trenches, pipelines, direct-buring and other fixed places capable of bearing large mechanical force.
KVV32 Copper core PVC insulated PVC sheathed steel tape armored control cable Laid indoors, and in cable trenches, pipelines, vertical shafts and other fixed places capable of bearing large mechanical force.
KVVR Copper core PVC insulated PVC sheathed, fine steel wire armored control cable Laid indoors in occasions requiring movement and flexibility.
KVVRP Copper core PVC insulated PVC sheathed flexible control cable Laid indoors in occasions requiring movement, flexibility and shielding.
KVVP2-22 Copper core PVC insulated PVC sheathed copper belt shield steel tape armored control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions capable of bearing large mechanical force and requiring shielding.

PVC Insulated Control Cable Range of production


Model
Rated voltage (V) Conductor nominal cross sectional area (mm2)
  0.75 1.0 1.5 2.5 4 6 10
KV  
 
 
 
450/750
- 2-61 2-14 2-10
KVVP
KVVP2   4-61 4-14 4-10
KVV22 - 7-61 4-61 4-14 4-10
KVVP2-22
KVV32 - 19-61 7-61 4-14 4-10
KVVR   4-61 - -
KVVRP 4-61 4-48 - -
Notes: The recommended number of cores is: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 37, 44, 48, 52 and 61

XLPE Insulated Control Cable 

This product is used for electrical appliance and instrument connecting cables in power distribution equipment with AC rated voltage of 450/750 V and below.
Its mechanical and physical properties and electrical performance meet the requirements in GB/T9330-2008 "XLPE Insulated Control Cable”.
 

Operating characteristics and electrical performance

1. Cable laying temperature: ≥0°C
2. Long-term allowable operating temperature of cable conductor: 90°C
3. Minimum permissible bending radius:
a. For unarmored cables, should be no less than 6 times of cable outer diameter;
b. For armored or copper belt shield structure cables, should be not less than 12 times of cable outer diameter;
c. For flexible cable with shield structure, shoud be less than six times of cable outer diameter.
4. Finished cable can bear AC 50HZ, 3 KV, 5min withstand test without breakdown.
5. Conductor DC resistance meets the requirements of national standard GB/T3956-2008 “Cable Conductor” and international standard IEC60228.
 

Models, Names and Laying Occasions of XLPE Insulated Control Cable

Model Name Laying Occasion
KYJV Copper core XLPE insulated PVC sheathed control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions.
KYJVP Copper core XLPE insulated PVC sheathed braid shield control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding.
KYJVP2 Copper core XLPE insulated PVC sheathed copper belt shield control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding.
KYJV22 Copper core XLPE insulated PVC sheathed steel tape armored control cable Laid indoors, and in cable trenches, pipelines, direct-buring and other fixed places capable of bearing large mechanical force.
KYJV32 KYJV32 Copper core XLPE insulated PVC sheathed fine steel wire armored control cable Laid indoors, and in cable trenches, pipelines, vertical shafts and other fixed places capable of bearing large mechanical force.
KYJVR Copper core XLPE insulated PVC sheathed flexible control cable Laid indoors in occasions requiring movement and flexibility.
KYJVRP Copper core XLPE insulated PVC sheathed braid shielding control cable Laid indoors in occasions requiring movement, flexibility and shielding.
KYJVP2-22 Copper core XLPE insulated PVC sheathed steel tape shielded steel plate armored control cable Laid indoors, and in cable trenches, pipelines and other fixed occasions capable of bearing large mechanical force and requiring shielding.

XLPE Insulated Control Cable Range of production


Model
Rated voltage (V) Conductor nominal cross sectional area (mm2)
  0.75 1.0 1.5 2.5 4 6 10
KYJV  
 
 
 
45O/750
- 2-61 2-14 2-10
KYJVP
KYJP2   4-61 4-14 4-10
KYJV22 - 7-61 4-61 4-14 4-10
KYJVP2-22
KYJV32 - 19-61 7-61 4-14 4-10
KYJVR   4-61 - -
KYJVRP 4-61 4-48 - -
Notes: The recommended number of cores is: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 37, 44, 48, 52 and 61.

0.6/1KV PVC/PVC Power cable (non-armored) VV, VLV


Conductor dimensions (mm2)
 
Insulation thickness (mm)
Nonmetallic sheath, unarmored cable
Sheath thickness Outer diameter (approximate) Cable weight (Kg/km)
mm mm Copper core Aluminum core
1C 2C 3C 4C 5C 1C 2C 3C 4C 5C 1C 2C 3C 4C 5C 1C 2C 3C 4C 5C
1.5 0.8 1.4 1.8 1.8 1.8 1.8 5.8 10.4 10.8 11.6 12.4 49 131 152 184 215 40 113 124 147 168
2.5 0.8 1.4 1.8 1.8 1.8 1.8 6.2 11.2 11.7 12.6 13.5 62 159 191 234 277 47 128 144 172 199
4 1.0 1.4 1.8 1.8 1.8 1.8 7.1 12.9 13.6 14.7 15.9 86 211 264 330 391 62 161 189 231 266
6 1.0 1.4 1.8 1.8 1.8 1.8 7.6 13.9 14.7 15.9 17.3 110 268 334 423 505 73 193 221 273 318
10 1.0 1.4 1.8 1.8 1.8 1.8 8.7 16.2 17.1 18.6 20.3 158 380 492 627 754 96 254 303 375 439
16 1.0 1.4 1.8 1.8 1.8 1.8 9.8 18.4 19.5 21.3 23.3 224 533 714 905 1094 124 331 412 502 590
25 1.2 1.4 1.8 1.8 1.8 1.8 11.2 21.2 22.5 24.7 27.1 325 759 1019 1307 1592 169 445 547 678 806
35 1.2 1.4 1.8 1.8 1.8 1.9 12.4 23.6 21.4 27.6 30.5 429 974 1313 1699 2098 211 533 652 818 997
50 1.4 1.4 1.8 1.8 1.9 2.1 14.0 26.8 28.0 31.6 35.2 590 1265 1781 2354 2929 278 636 837 1096 1355
70 1.4 1.4 1.9 2.0 2.1 2.2 15.6 23.4 27.2 31.5 37.9 791 1650 2393 3155 3942 353 770 1071 1394 1740
95 1.6 1.5 2.0 2.1 2.2 2.4 17.9 27.2 31.4 36.6 43.0 1062 2206 3205 4239 5295 467 1011 1412 1849 2307
120 1.6 1.5 2.1 2.2 2.4 2.5 19.3 29.8 34.3 39.2 46.9 1306 2727 3966 5244 6549 555 1217 1701 2224 2774
150 1.8 1.6 2.2 2.3 2.5 2.7 21.4 32.6 37.9 43.1 52.4 1625 3374 4924 6508 8155 686 1486 2093 2733 3437
185 2.0 1.7 2.4 2.5 2.7 2.9 23.7 38.6 42.3 48.2 60.7 1998 4185 6062 8022 10074 840 1857 2571 3366 4254
240 2.2 1.8 2.6 2.7 2.9 3.1 26.5 43.8 49.7 55.7 65.8 2565 5371 7825 10335 12911 1062 2351 3296 4295 5361
300 2.4 1.9 2.7 2.9 3.1 3.3 29.3 48.8 52.8 62.3 71.4 3186 6641 9696 12859 16023 1306 2854 4016 5285 6557
400 2.6 2.0   3.1 3.4 3.7 33.0   59.8 71.2 83.1 4191   12739 16940 21124 1684   5165 6842 8501
500 2.8 2.1   3.4 3.4   36.4   74.2 82.2 86.5 5198   15898 20937   2064   6431 8314  
630 2.8 2.2         40.1   77.0 85.3   6464         2515        
800 2.8 2.3         45.2         8126         3112        
1000 3.0 2.5         50.5         10120         3853        

If you need more details, pls email us:info@uni-fibercable.com


Contact Us, Now.
24-hour service hotline
Contact online customer service
Add: Technology Building, Tongbai Road, Zhongyuan District, Zhengzhou, Henan, China.
Related products
U1000 R2V Series Cable Industrial and Tertiary Cables
U1000 R2V Series Cable Industrial and Tertiary Cables
Armoured Cable SWA & AWA
Armoured Cable SWA & AWA
6/10KV 12/20KV 18/30KV N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable
6/10KV 12/20KV 18/30KV N2XSEY NA2XSEY N2XSE2Y NA2XSE2Y Three Cores Cable
6/10 kV 12/20 kV 18/30 kV N2XSY NA2XSY N2XS2Y NA2XS2Y N2XS(F)2Y NA2XS(F)2Y N2XS(FL)2Y NA2XS(FL)2Y Single Core Cable
6/10 kV 12/20 kV 18/30 kV N2XSY NA2XSY N2XS2Y NA2XS2Y N2XS(F)2Y NA2XS(F)2Y N2XS(FL)2Y NA2XS(FL)2Y Si
Related cases
fibra optica PKP multi loose tube cable price from China
Available up to 216 Fibres Fibra Optica PKP Multitube Loose Tube Outdoor Cable
Available up to 216 Fibres Fibra Optica PKP Multitube Loose Tube Outdoor Cable Fibra Optica PKP DescriptionGel filled multi loose tube cable of double jacket fo
U-1000 R2V & RVFV Cables
U-1000 R2V & RVFV Cables for Algeria
U-1000 R2V & RVFV Cables for AlgeriaU-1000 R2V & RVFV CablesIndustry: Building & Construction, Transmission, Distribution & Power Networks Standard: NF C32-322
Air Blown Micro Fiber Optical Cable
Air Blown Micro Fiber Optical Cable
Air Blown Micro Fiber Optical CableAir-blown micro-cables & micro-tubes, applied in a variety of application scenarios, improve the utilization ratio of pipe ho