YOUR CURRENT POSITION: Home > Case > Africa
U-1000 R2V & RVFV Cables for Algeria
Release time: 2024-05-11

U-1000 R2V & RVFV Cables for Algeria

U-1000 R2V & RVFV Cables

Industry: Building & Construction, Transmission, Distribution & Power Networks
Standard: NF C32-322
Type: Armoured Cable – SWA & AWA, Industrial Cable, Power Network & Local Distribution Cable
Our U-1000 cables are manufactured in accordance with French Norms (U-1000 R2V: NF C 32-322 / U-1000 RVFV: NF C 32-321). They are low voltage fixed wiring in armoured and unarmoured variants.

R2V and RVFV Cable Specification

R2V cable (also known as XV or RV cable) are rigid unarmoured power and control cables, whilst U-1000 RVFV cable (also known as XAV cable) are the armoured equivalent. They are used for the supply of electricity in a wide range of semi-industrial and industrial applications with a voltage rating of 600/1000V. This including lighting remote control and telecontrol installation systems, and other electrical devices.
The U-1000 R2V cable can be fixed on cable trays, within conduits or to walls. The U-1000 RVFV is constructed with additional two layers of steel tape armouring and so can also be used outdoors and in direct burial installations or where additional protection against mechanical stresses is required. The U-1000 RVFV is not recommended for burial in areas that are flooded for more than two months per year or in trenches used as drains.

R2V & RVFV Cables Construction Table

  U-1000 R2V/ XV/ RV CABLE U-1000 RVFV / XAV XLPE PVC 0.6/1KV CABLE
VOLTAGE 0.6/1kV
CONDUCTOR Class 1 Solid or Class 2 Stranded Copper
INSULATION XLPE (Cross-Linked Polyethylene)
INNER SHEATH PVC (Polyvinyl Chloride)
ARMOUR - Two Steel Tapes
OUTER SHEATH PVC-FR (Polyvinyl Chloride Flame Retardant) PVC (Polyvinyl Chloride)

0.6 / 1 kV U-1000 RVFV Cable Parameter

NO. OF CORES NOMINAL CROSS SECTIONAL AREA NOMINAL OVERALL DIAMETER NOMINAL WEIGHT
mm2 mm kg/km
2 1.5 13 215
2 2.5 14 249
2 4 15.5 309
2 6 16.5 386
2 10 18.5 515
2 16 20.5 709
2 25 23.5 1063
3 2.5 14.5 274
3 4 16 352
3 6 17.5 447
3 10 19 624
3 16 22 849
3 25 25 1273
3 35 32.5 1644
3 50 37.5 2107
3 70 35 2862
3 95 40 * 4190
3 120 45 5176
3 150 50 6303
3 185 54 7698
3 240 63 9814
3 50 34.5 2560
3 70 40 3492
3 95 45 4790
3 120 50 5951
3 150 54 7090
5 1.5 15.5 301
5 2.5 17 373
5 4 18.5 480
5 6 20.5 638
5 10 22.5 900
5 16 26 1250
5 25 31 1903
5 35 32 2455

0.6 / 1 kV U-1000 R2V/XV/RV Cable Parameter

Single core
Size Cross-Section in mm2 Perm. Current rating open air A Perm. Current rating burried A Voltage drop, 3 conductors V/A.km Max. outer diameter mm Nominal overall cable weight kg/km
1.5 24 34 21.5 6.4 50
2.5 33 46 13.2 7.0 50
4 45 59 8.3 7.6 80
6 58 74 5.6 8.2 100
10 80 101 3.3 9.2 145
16 107 128 2.1 10.5 205
25 138 144 1.4 10.5 290
35 169 174 1.0 11.5 390
50 207 206 0.78 12.6 510
70 268 254 0.56 14.7 720
95 328 301 0.43 16.3 970
120 382 343 0.36 17.8 1210
150 441 387 0.31 20.2 1480
185 506 434 0.26 22.1 1835
240 599 501 0.22 24.9 2540
300 693 565 0.19 27.7 2945
400 825 662 0.17 31.6 2860
500 946 750 0.15 35.5 4890
Two cores
Size Cross-Section in mm2 Perm. Current rating open air A Perm. Current rating burried A Voltage drop, 3 conductors V/A.km Max. outer diameter mm Nominal overall cable weight kg/km
1.5 24.8 10.5 24 34 130
2.5 14.8 11.5 33 46 170
4 9.2 13.0 45 59 220
6 6.2 14.0 58 74 290
10 3.7 16.0 80 101 400
16 2.4 18.5 107 128 550
25 1.6 22.0 142 162 865
35 1.15 22.4 185 208 1145
50   24.2 225 247 1435
Three cores
Size Cross-Section in mm2 Perm. Current rating open air A Perm. Current rating burried A Voltage drop, 3 conductors V/A.km Max. outer diameter mm Nominal overall cable weight kg/km
1.5 21.4 11.0 22 29 145
2.5 13.2 12.5 30 40 190
4 8.2 13.5 40 51 250
6 5.5 15.0 52 64 340
10 3.3 17.0 71 88 485
16 2.1 16.5 96 111 690
25 1.37 23.5 127 144 1080
35 1.0 26.0 158 174 1435
50 0.76 29.0 192 206 1845
70 0.55 34.0 246 254 2560
95 0.42 38.5 298 301 3470
120 0.35 42.5 346 343 4410
150 0.30 47.5 395 387 5330
185 0.25 53.0 450 434 6570
240 0.19 59.5 538 501 8460
Three cores with smaller neutral conductor
Size Cross-Section in mm2 Perm. Current rating open air A Perm. Current rating burried A Voltage drop, 3 conductors V/A.km Max. outer diameter mm Nominal overall cable weight kg/km
50 0.78 31.1 35 190 204
70 0.55 35.1 35 242 252
70 0.57 36.2 50 242 252
95 0.44 40.6 50 293 302
120 0.36 45.4 70 339 345
150 0.31 49.5 70 390 386
240 0.23 61.5 95 522 504
Four cores
Size Cross-Section in mm2 Perm. Current rating open air A Perm. Current rating burried A Voltage drop, 3 conductors V/A.km Max. outer diameter mm Nominal overall cable weight kg/km
1.5 21.5 12.0 22 26 170
2.5 12.8 13.0 30 36 220
4 8.0 14.5 40 46 300
6 5.4 16.0 52 58 410
10 3.2 18.5 71 79 600
16 2.11 21.0 96 100 860
25 1.37 25.5 127 141 1340
35 1.0 28.5 158 174 1780
50 0.76 32.5 192 206 2330
70 0.55 34.5 246 254 3375
95 0.42 42.5 298 301 4345
120 0.35 47.5 346 343 5590
150 0.3 52.5 395 387 6650
185 0.25 59.0 450 434 8350
Five cores
Size Cross-Section in mm2 Perm. Current rating open air A Perm. Current rating burried A Voltage drop, 3 conductors V/A.km Max. outer diameter mm Nominal overall cable weight kg/km
1.5 21.5 13.0 22 26 200
2.5 13.2 14.5 30 36 275
4 8.2 16.0 30 46 365
6 5.5 17.5 52 58 490
10 3.3 20.0 71 79 725
16 2.1 23.0 96 100 1060
25 1.37 28.0 127 141 1610
35 1.0 30.5 157 170 2210
50 0.76 34.0 190 204 2930
70 0.54 43.0 242 252 4150
95 0.15 47.0 293 302 5540

How to Order R2V & RVFV Cables Price

Our team is committed to providing outstanding service before, during, and after the sale. To learn more about our products or to place an order, please contact your sales representative. Email us at info@uni-fibercable.com
Related products
OPGW Optical Ground Wire - Aluminum Clad Steel Tube
Aluminum Clad Steel Tube - OPGW Optical Ground Wire
U1000 R2V Series Cable Industrial and Tertiary Cables
U1000 R2V Series Cable Industrial and Tertiary Cables
ACSR-Aluminum Conductor Steel Reinforced
ACSR-Aluminum Conductor Steel Reinforced
Covered Protected Aluminum Cable (ABNT NBR 11873)
Covered Protected Aluminum Cable (ABNT NBR 11873)