Armoured Cable SWA & AWA Description
These include low voltage and medium voltage SWA steel wire armour 3 core cable, and all sizes of these widely used armoured power cables with current ratings up to 33kV. For single core cables, aluminium wire armour - AWA - is used to prevent induced current in the armour. Armoured power cables are available with both copper and aluminium conductors as required.The armour provides additional protection where mechanical stress has the potential to cause damage to the cable, such as direct burial, outdoors or underground. The armour also enables the cable to withstand higher pulling loads. It should be noted, however, that the armour provides no protection for climatic conditions.
Armoured cables are often referred to as steel wire armoured cables, SWA cable, mains power cable, single core power cable, and multi-core booklet armoured cable.
AWA & SWA Armoured Cable Construction
Typically, the construction of an aluminium or steel wire armored cable comprises six components:- Conductor: plain stranded copper or aluminium
- Insulation: materials such as cross-linked polyethylene (XLPE) provide high temperature resistance and excellent dielectric strength-providing enhanced electrical properties.
- Bedding: a layer to create a protective barrier between the insulation and the armour.
- Armour: a steel or aluminium armour provides mechanical protection to allow the cable to withstand the mechanical stresses to which it is exposed.
- Sheath: the constituent parts of the cable are held together by a sheath offering a further level of protection. Black sheaths can be carbon-loaded for UV stability.
- Voltage: voltage ratings of 600/1000V, 6.35/11kV and 19/33kV.
ARMOURED CABLE - SWA & AWA TYPES
BS 5467 SWA PVC BASEC Multi Core 0.6/1kV Cable |
BS 6724 SWA LSZH BASEC Multi Core 0.6/1kV Cable |
BS 5467 AWA PVC BASEC Single Core 0.6/1kV Cable |
BS 6724 AWA LSZH BASEC Single Core 0.6/1kV Cable |
BS 5467 Single Core XLPE AWA PVC 1.9/3.3kV Cable |
BS 5467 Multicore XLPE SWA PVC 1.9/3.3kV Cable |
BS 5467 Multicore Sectoral Shaped XLPE SWA PVC 1.9/3.3kV cable |
BS 6724 Single Core XLPE AWA LSZH 1.9/3.3kV Cable |
BS 6724 Multicore XLPE SWA LSZH 1.9/3.3kV Cable |
BS 6724 Multicore Sectoral Shaped XLPE SWA LSZH 1.9/3.3kV Cable |
BS6622 XLPE PVC 3.8/6.6kV Cable |
BS6622 Aluminium XLPE PVC 3.8/6.6kV Cable |
BS 6622 XLPE PVC 6.35/11 (12)kV Cable |
BS 6622 XLPE / PVC Medium Voltage 19/33 (36)kV Cable |
BS 6622 XLPE MDPE 6.35/11 (12)kV Cable |
BS7835 XLPE LSZH 3.8/6.6kV Cable |
BS7835 Aluminium XLPE LSZH 3.8/6.6kV Cable |
BS7835 XLPE LSZH 6.35/11 (12)kV Cable |
BS7835 XLPE LSZH 19/33 (36)kV Cable |
NA2XRY Aluminium Conductor IEC 60502-1 XLPE SWA PVC 0.6/1kV Cable |
NA2XRH Aluminium Conductor IEC 60502-1 XLPE SWA HFFR 0.6/1kV Cable |
N2XRY Cable |
N2XRH Cable |
RZ1MZ1-K Cable |
Traffic Signal Cable BS6346 SWA PVC |
N2XFGbY Cable 0.6/1kV |
NYFGBY Cable |
N2XBH Cable |
N2XBY Cable |
NYBY Cable |
U-1000 ARVFV 1kV Cable |
U-1000 RVFV / XAV XLPE PVC 0.6/1kV Cable |
NYFGY 3.6/6kV Cable |
SANS 1507-4 XLPE-SWA-PVC 1kV Cable |
SANS 1507-3 PVC-SWA-PVC 1kV Cable |
Armoured AS/NZS 5000.1 XLPE PVC 1kV Cable |
Armoured Hydrocarbon Resistant Power 1kV Cable |
BS6622 XLPE PVC 8.7/15kV Cable |
BS7835 XLPE LSZH 8.7/15kV Cable |
BS6622 XLPE PVC 12.7/22kV Cable |
BS7835 XLPE LSZH 12.7/22kV Cable |