YOUR CURRENT POSITION: Home > Product > Instrumentation Cables
Fire Resistant Instrumentation Cables

Fire Resistant Instrumentation Cables

CU/MT/XLPE/OS/LSZH; CU/MT/XLPE/IS/OS/LSZH; CU/MT/XLPE/OS/LSZH/SWA/LSZH; CU/MT/XLPE/IS/OS/LSZH/SWA/LSZH

Fire resistant Instrumentation Cables 300 V EN 50288-7 IEC 60331-23

 

Fire resistant Instrumentation Cables Product features

  • CU/MT/XLPE/OS/LSZH: Twisted pair or triad signal cable, overall screened, XLPE over MICA-tape insulated and LSZH jacketed 
  • CU/MT/XLPE/IS/OS/LSZH: Twisted pair or triad signal cable, individual and overall screened, XLPE over MICA-tape insulated and LSZH jacketed
  • CU/MT/XLPE/OS/LSZH/SWA/LSZH: Armoured twisted pair or triad signal cable, overall screened, XLPE over MICA-tape insulated and LSZH jacketed
  • CU/MT/XLPE/IS/OS/LSZH/SWA/LSZH: Armoured twisted pair or triad signal cable, individual and overall screened, XLPE over MICA-tape insulated and LSZH jacketed

 Fire resistant Instrumentation Cables Benefits

  • • Sunlight resistant
  • • Hydrocarbon and Chemical resistant
  • • Fire behaviour
  • • Oil resistant

Fire resistant Instrumentation Cables Norm references / Approvals

  • • Hydrocarbon & Oil resistance CEI 20-34/0
  • • Smoke IEC 61034-1 and 2
  • • Halogen acid gas IEC 60754-1 and 2
  • • Fire behaviour IEC 60332-1-2 IEC 60332-3-22 (Cat. A) IEC 60331-23 (90 min./750°C)

Fire resistant Instrumentation Cables Design

  • • Conductor: Stranded Annealed Copper
  • • Core insulation: XLPE, over MICA-tape wrapped conductor
  • • Screen: OS Aluminum/PET + TC Drain wire
  • • Outer sheath: LSZH, black

Fire resistant Instrumentation Cables Technical data

  • Core identification code: Pairs are black & white with printed
  • numbers; Triads are black, white, red with printed numbers
  • Insulation resistance: 5000 MOhm x km
  • Conductor stranding: Class 2 IEC 60228
  • Nominal Voltage Uo/U: 300/300 V
  • Test voltage: C/C 1500 V x 1 minute
  • Temperature range: during operation: -30° to +70°C
  • during installation: -5° to +50°C
  • Minimum Bending Radius: 8 x Outer Diameter

Fire resistant, overall screened instrumentation cable LSZH CU/MT/XLPE/OS/LSZH

Number cores and mm2 per conductor Approx. Outer Diameter (mm) Copper index (kg/km) Approx. Weight (kg/km)
1x2x0,5 6,6 15,1 47
2x2x0,5 9,7 25,4 93
6x2x0,5 13,7 66,7 185
10x2x0,5 17,8 108,0 285
12x2x0,5 18,4 128,7 308
16x2x0,5 20,7 170,0 401
20x2x0,5 23,3 211,3 511
24x2x0,5 26,0 252,6 593
30x2x0,5 27,5 314,6 690
1x3x0,5 6,9 20,2 56
3x3x0,5 11,6 51,2 135
6x3x0,5 15,4 97,7 251
10x3x0,5 20,1 159,7 389
12x3x0,5 20,8 190,6 427
1x2x0,75 7,0 20,2 54
2x2x0,75 10,4 35,7 111
6x2x0,75 15,0 97,5 235
10x2x0,75 19,3 159,4 352
12x2x0,75 20,2 190,3 395
16x2x0,75 22,4 252,2 504
20x2x0,75 25,2 314,0 642
24x2x0,75 28,1 375,9 747
30x2x0,75 30,0 468,7 890
1x3x0,75 7,4 27,9 67
3x3x0,75 12,5 74,3 166
6x3x0,75 16,7 143,9 312
10x3x0,75 21,8 236,7 487
12x3x0,75 22,5 283,1 539
1x2x1 7,4 25,6 62
2x2x1 11,0 46,5 128
6x2x1 15,9 130,1 278
10x2x1 20,7 213,6 430
12x2x1 21,4 255,4 472
16x2x1 24,0 338,9 619
20x2x1 27,0 422,5 786
24x2x1 30,2 506,0 915
30x2x1 32,2 631,4 1.094
1x3x1 7,8 36,1 77
3x3x1 13,3 98,7 196
6x3x1 17,9 192,7 382
10x3x1 23,4 318,0 597
12x3x1 24,2 380,7 664
1x2x1,5 8,2 36,5 78
2x2x1,5 12,6 68,2 171
6x2x1,5 18,2 195,1 378
10x2x1,5 23,7 322,1 587
12x2x1,5 24,5 385,5 649
16x2x1,5 27,5 512,5 852
20x2x1,5 30,9 639,4 1.083
24x2x1,5 34,8 766,3 1.279
30x2x1,5 37,1 956,7 1.532
1x3x1,5 8,9 52,3 104
3x3x1,5 15,2 147,5 267
6x3x1,5 20,5 290,3 524
10x3x1,5 26,8 480,7 821
12x3x1,5 27,7 575,9 919

Fire resistant, individual and overall screened instrumentation cable LSZH CU/MT/XLPE/IS/OS/LSZH

Number cores and mm2 per conductor Approx. Outer Diameter (mm) Copper index (kg/km) Approx. Weight (kg/km)
2x2x0,5 10,6 35,7 114
6x2x0,5 15,3 97,7 247
10x2x0,5 19,7 159,7 374
12x2x0,5 20,6 190,6 422
16x2x0,5 23,1 252,6 550
20x2x0,5 25,9 314,6 696
24x2x0,5 29,0 376,6 813
30x2x0,5 30,7 469,5 957
3x3x0,5 12,8 66,7 165
6x3x0,5 17,2 128,7 318
10x3x0,5 22,2 211,3 483
12x3x0,5 23,2 252,6 548
2x2x0,75 11,6 46,0 139
6x2x0,75 16,4 128,5 293
10x2x0,75 21,5 211,0 456
12x2x0,75 22,2 252,3 504
16x2x0,75 24,9 334,8 659
20x2x0,75 28,0 417,3 835
24x2x0,75 31,5 499,8 991
30x2x0,75 33,4 623,6 1.17
3x3x0,75 13,7 89,8 197
6x3x0,75 18,6 174,9 382
10x3x0,75 24,2 288,3 597
12x3x0,75 25,1 345,1 666
2x2x1 12,3 56,8 157
6x2x1 17,7 161,0 346
10x2x1 23,0 265,3 539
12x2x1 23,8 317,4 597
16x2x1 26,7 421,6 781
20x2x1 30,0 525,8 988
24x2x1 33,6 630,0 1.154
30x2x1 35,8 786,3 1.386
3x3x1 14,8 114,2 235
6x3x1 19,7 223,7 446
10x3x1 26,0 369,7 713
12x3x1 26,9 442,7 797
2x2x1,5 13,8 78,5 196
6x2x1,5 20,1 226,1 453
10x2x1,5 26,2 373,7 706
12x2x1,5 27,1 447,5 784
16x2x1,5 30,4 595,1 1.028
20x2x1,5 34,4 742,7 1.319
24x2x1,5 38,5 890,3 1.539
30x2x1,5 41,0 1111,6 1.849
3x3x1,5 16,6 163,0 302
6x3x1,5 22,5 321,3 594
10x3x1,5 29,6 532,4 947
12x3x1,5 30,6 637,9 1.063

Fire resistant, armoured overall screened instrumentation cable LSZH CU/MT/XLPE/OS/LSZH/SWA/LSZH

Number cores and mm2 per conductor Approx. Outer Diameter (mm) Copper index (kg/km) Approx. Weight (kg/km)
1x2x0,5 11,2 15,1 221
2x2x0,5 14,5 25,4 341
6x2x0,5 18,7 66,7 527
10x2x0,5 23,8 108,0 852
12x2x0,5 24,6 128,7 905
16x2x0,5 26,9 170,0 1.062
20x2x0,5 29,7 211,3 1.259
24x2x0,5 32,6 252,6 1.436
30x2x0,5 34,9 314,6 1.764
1x3x0,5 11,5 20,2 238
3x3x0,5 16,7 51,2 433
6x3x0,5 20,7 97,7 642
10x3x0,5 26,3 159,7 1.034
12x3x0,5 27,0 190,6 1.092
1x2x0,75 11,6 20,2 238
2x2x0,75 15,3 35,7 374
6x2x0,75 20,0 97,5 605
10x2x0,75 25,5 159,4 974
12x2x0,75 26,3 190,3 1.04
16x2x0,75 28,8 252,2 1.228
20x2x0,75 31,6 314,0 1.446
24x2x0,75 35,5 375,9 1.844
30x2x0,75 37,6 468,7 2.072
1x3x0,75 12,0 27,9 259
3x3x0,75 17,6 74,3 482
6x3x0,75 22,7 143,9 848
10x3x0,75 28,2 236,7 1.194
12x3x0,75 28,9 283,1 1.268
1x2x1 12,0 25,6 254
2x2x1 15,9 46,5 404
6x2x1 21,9 130,1 791
10x2x1 26,9 213,6 1.092
12x2x1 27,6 255,4 1.155
16x2x1 30,4 338,9 1.39
20x2x1 34,4 422,5 1.844
24x2x1 37,8 506,0 2.104
30x2x1 39,8 631,4 2.354
1x3x1 12,6 36,1 285
3x3x1 18,3 98,7 529
6x3x1 23,9 192,7 953
10x3x1 29,8 318,0 1.35
12x3x1 30,6 380,7 1.441
1x2x1,5 13,0 36,5 294
2x2x1,5 17,7 68,2 490
6x2x1,5 24,4 195,1 967
10x2x1,5 30,1 322,1 1.349
12x2x1,5 30,9 385,5 1.434
16x2x1,5 34,8 512,5 1.926
20x2x1,5 38,5 639,4 2.297
24x2x1,5 42,5 766,3 2.65
30x2x1,5 45,9 956,7 3.291
1x3x1,5 13,8 52,3 335
3x3x1,5 20,4 147,5 652
6x3x1,5 26,7 290,3 1.18
10x3x1,5 34,1 480,7 1.869
12x3x1,5 35,0 575,9 2

Fire resistant, armoured individual and overall screened instrumentation cable LSZH CU/MT/XLPE/IS/OS/LSZH/SWA/LSZH

Number cores and mm2 per conductor Approx. Outer Diameter (mm) Copper index (kg/km) Approx. Weight (kg/km)
2x2x0,5 15,5 35,7 382
6x2x0,5 20,5 97,7 634
10x2x0,5 25,9 159,7 1.007
12x2x0,5 26,8 190,6 1.08
16x2x0,5 29,5 252,6 1.294
20x2x0,5 32,6 314,6 1.538
24x2x0,5 36,5 376,6 1.957
30x2x0,5 38,3 469,5 2.163
3x3x0,5 17,8 66,7 488
6x3x0,5 23,2 128,7 868
10x3x0,5 28,6 211,3 1.203
12x3x0,5 29,6 252,6 1.295
2x2x0,75 16,7 46,0 435
6x2x0,75 22,4 128,5 822
10x2x0,75 27,7 211,0 1.14
12x2x0,75 28,6 252,3 1.223
16x2x0,75 31,3 334,8 1.456
20x2x0,75 35,4 417,3 1.928
24x2x0,75 39,1 499,8 2.226
30x2x0,75 41,2 623,6 2.493
3x3x0,75 18,8 89,8 540
6x3x0,75 24,8 174,9 982
10x3x0,75 30,6 288,3 1.375
12x3x0,75 31,5 345,1 1.467
2x2x1 17,3 56,8 468
6x2x1 23,6 161,0 909
10x2x1 29,4 265,3 1.281
12x2x1 30,2 317,4 1.362
16x2x1 34,1 421,6 1.827
20x2x1 37,6 525,8 2.17
24x2x1 41,3 630,0 2.482
30x2x1 43,6 786,3 2.793
3x3x1 19,8 114,2 601
6x3x1 25,9 223,7 1.079
10x3x1 32,6 369,7 1.556
12x3x1 34,2 442,7 1.849
2x2x1,5 18,8 78,5 541
6x2x1,5 26,3 226,1 1.098
10x2x1,5 32,8 373,7 1.556
12x2x1,5 34,5 447,5 1.846
16x2x1,5 38,0 595,1 2.224
20x2x1,5 42,2 742,7 2.677
24x2x1,5 47,3 890,3 3.358
30x2x1,5 50,0 1111,6 3.801
3x3x1,5 22,6 163,0 836
6x3x1,5 28,9 321,3 1.32
10x3x1,5 37,2 532,4 2.113
12x3x1,5 38,2 637,9 2.267

Contact Us, Now.
24-hour service hotline
Contact online customer service
Add: Technology Building, Tongbai Road, Zhongyuan District, Zhengzhou, Henan, China.
Related products
Multicore Multipair EN 50288-7 Fire resistant Instrumentation Cables
Multicore Multipair EN 50288-7 Fire resistant Instrumentation Cables
Individual and Overall Screened instrumentation cables
BS5308 instrumentation cables
French Normes NF M 87-202 Standard Cables
French Normes NF M 87-202 Standard Cables
Armored Instrumentation Cables
Armored Instrumentation Cables
Related cases
Peru MV-LV POWER CABLE / AAAC  / AAAC-S (CAAPI) / ABC CABLE
Supply Peru MV-LV POWER CABLE / AAAC / AAAC-S (CAAPI) / ABC CABLE
Supply Peru MV-LV POWER CABLE / AAAC / AAAC-S (CAAPI) / ABC CABLE MV POWER CABLES MV POWER CABLE N2XSY 8,7/15 KV : SINGLE CORE 1x50mm&sup
AWAC Cable (AS/AC ) Wire for Africa
AWAC Cable (AS/AC ) Wire for Africa
AS/AC (AWAC) conductors are used as phase conductors to increase span length or clearances, neutral messengers for spacer cables, ground or shield wires, and as self-supporting cables.
Overhead Transmission Line Conductor
Bangladesh Inquiry for Hardware for Overhead Transmission line
Inquiry for Hardware for Overhead Transmission lineBangladesh Power Development Board is interested to purchase Bare & Insulated Conductors along with hardware